Model | SX3 |
Brand | Arphi |
Grade | Medical Grade |
Usage/Application | Pure Tone Audiometry |
Weight | 1.7 Kg |
Display | LCD |
Dimension | 275x200x80 mm |
Voltage | 270 V AC |
Guarantee | 1 Year |
Type of Audiometer | Diagnostic |
Frequency | 50 Hz |
Proton SX 3 Audiometer
Test: AC, BC, Masking, Speech, Free Field
along with B 71 Bone Conductor
, TDH 39 P Head Phone
Minimum Order Quantity | 1 Piece |
Brand | ARPHI |
Grade | Medical Grade |
Usage/Application | Pure Tone Audiometry |
Model Number | Proton SX3 |
Weight | 900g |
Display | LCD |
Type of Audiometer | Diagnostic |
Proton SX 3 Audiometer
It is a pure tone audiometer. An audiometer is a medical device used to assess an individual's hearing abilities. It presents a range of sounds at different frequencies and volumes to the person being tested, and the individual responds to indicate when they hear the sounds. This allows healthcare professionals, particularly audiologists, to determine the patient's hearing thresholds and diagnose any hearing loss or hearing-related conditions.
Model | DX5 |
Brand | ARPHI |
Grade | Medical Grade |
Type of Audiometer | Diagnostic |
Frequency | Better than +- 2% |
Hearing Level Electrical | Within +- 1%dB of indication |
Acoustical | Within +- 3db of indication |
Connectivity | USB output in Model SX 3 & SX 5 |
Screen Dimension | 155 x 16mm.with LED Backlighting |
The PROTON is a new generation 100% Digital Audiometer available in basic version the DX 3 and thediagnostic version the DX 5. This audiometer also features an optional user-friendly PC software, thePROTON SX 3 and the PROTON SX 5 with software is designed for unidirectional operation for optimaloperating efficiency during daily routine examinations. New features incorporated into the PROTONinclude, amongst other, data interface, ipsilateral masking, and simultaneous presentation of stimulusand masking binaurally.
State-of-the art technology has enabled us to produce a compact lightweight instrument not only capableof performing the standard battery of tests but also featuring many other advanced and innovativefacilities.
All these features have been incorporated into a striking simple user friendly and ergonomic design, whichmakes operation fast, easy and efficient.
Acompletely new attenuator which permits totally click free operation over the entire attenuator range.Simple menu-driven dialogue makes the PROTON easy to learn and easy to use. Working with menu drivendisplay is uncomplicated, the display itself is easily readable under any lighting conditions and from anyviewing angle thanks to state-of the-art LCD technology.
The PROTON SX software saves patient audiograms and sessions for recall, review and printing.
*Your information is safe with us.
Model Name/Number | Proton Dx 3 |
Usage | Hospital |
Brand | Arphi |
Weight | 1.7 Kg |
Screen dimensions | 155 x 16 mm with LED back light |
Attenuator Range | -10 to 120 dB steps with Range Extender function. Fully click free operation over entire range |
Frequency | 250-8000 Hz |
Speech Audiometry | Stimulus via Microphone or Tape/CD |
Masking | Wide Band |
Hearing Level Range | 70 dB HL at 500-4000 Hz,60 Db at 250 Hz |
Tone | Continuous,Pulsed,Pulsing Rate 1.5 Hz |
Hearing Level Range Air | Max 120 dB HLat 500-6000 Hz. Max 110 Db.at 250 Hz,Max 100 Db.at 8000 Hz |
Special Tests | Tone Decay Test,Speech Test (Pulse counter display) |
Make Arphi
Model Proton DX3
An audiometer is a medical device used to assess an individual's hearing abilities. It presents a range of sounds at different frequencies and volumes to the person being tested, and the individual responds to indicate when they hear the sounds. This allows healthcare professionals, particularly audiologists, to determine the patient's hearing thresholds and diagnose any hearing loss or hearing-related conditions.
Grade | Medical Grade |
Usage/Application | Audiology |
Model Name/Number | Audiolab + |
Brand | Labat |
Display | Digtial |
Air Conduction | 10 dB HL to +120 dB HL |
Type Of Audiometer | Diagnostic |
Bone Conduction | 10 dB HL to +75 dB HL |
Features
Diagnostic Digital Audiometer
Touch Key Operation
Automatic Synchronized Tone and Masking
Customized & Auto Generated Report Through PC
Unlimited Test Memory
Sturdy Built For Longevity
Highly Portable
Usage/Application | Hospital |
Model Number | 2001 |
Weight | 5 Kg |
Band | ARPHI |
Dimension | 400x330x135 mm |
Power Supply | 230 V AC, 50 HZ +10% |
Operating Temperature | 15 to 50 Deg C |
Relative Humidity | 30-90 % RH |
The 2001 Is a New Generation Digital Audiometer From Arphi.
Technical Specification
Test : AC,BC,Tone Decay, Speech
Special Test :SISI,ABLB,STENGER
Input: tone,speech,tape,pulsetone
Output : Output : Left Right ,Bone L+R,FF Left ,FF Right ,FF L+R
*Your information is safe with us.
Usage | Hospital |
Brand | Labat |
Usage/Application | Audiometry |
Model Number | Audio Lite Pro |
Display | LCD |
Pulsed | 2.5 Hz,50%,200+200 mS |
Usage | Hospital |
Type Of Audiometer | Diagnostic |
Brand | LABAT |
Grade | Medical Grade |
Usage/Application | Hospital |
Model Number | Audiolab plus, Audiolab+ |
Weight | 260 Gram |
Resolution | 16 Bit |
Precision | +- 50 ppm |
Stability | +- 100 ppm |
Ratio signal/noise | 100dB |
Storage Temperature | -20 to 50 Deg C |
Operating Temperature | 5 to 40 Deg C |
Relative Humidity | 10-90 % RH |
Dimensions | 9,5 (w) x 15,7 (d) x 3 (h) cm |
Audiolab Plus is a True Hybrid Audiometer dedicated to provide you the best experience of the technological advancement happened in audiometers over the period in the Field of Audiology. It gives audiologist the seamless flexibility to use it as a Stand Alone as well as with PC. Its advanced soware Audiosoft also enables the audiologist to use it via Touch screen devices.
Features:
Truly HYBRID - Works Stand-Alone as well as Touch enabled operaon with touch based PC/Laptop
Auto Synchronized Tone and Masking
2 Independent Channels
No frequent calibraon
Real me plong and updang of color coded Audiogram and Results.
LIVE voice, Embedded Speech (with Automated Speech Scorer) and Local Words* (No CD Player Required)
Unlimited test memory on the device itself (more than 1 cr.)
Advanced COR with on device controls
Highly Portable and study built for longevity